Filter Results By:

Products

Applications

Manufacturers

Showing results: 181 - 186 of 186 items found.

  • High Performance Programmable AC Power Supply

    IT7600 Series - I-TECH Electronic Co., Ltd

    IT7600series high performance programmable AC power supplies, adopt advanced digital signal processing technology, with frequency up to 10-5000 Hz, built-inall-round power meter and large-screen oscilloscope function. Power up to 54kVA and support master-slave parallel, which can provide high-capacitysingle-phase or three-phase AC output. Some single-phase or three-phase products can be easily upgraded toAC600V (three-phase star connection downline voltage up to 1000V) output. IT7600 has built-in arbitrary waveform generator to simulate the harmonic and avariety of arbitrary waveforms output; also has strong exchange measurement and analysis functions. IT7600 can be widely used in many areas, such as newenergy, home appliances, power electronics, avionics, military, the development and application of IEC standard test and so on.

  • Network Analyzer

    DPNA-6G AXIe - Holding Informtest

    The AXI DPNA-6G module is the world's first network analyzer in the form factor of the AXIe-1 module, as well as the first Russian device that meets the AXIe-1 standard. In the mode of the network parameters meter, the AXI DPNA-6G module measures the vector values ​​of the network parameters on two ports: transmission coefficients (S12, S21) and reflection (S11, S22). At the same time, all necessary types of calibrations are supported: one- and two-port short-circuit, XX, matched load, transmission normalization. The software supports the import of third party calibration standard parameters. In the measuring receiver mode, the module provides:*generation of a harmonic signal (frequency synthesizer);*spectrum analyzer and power level in a given band;*measuring the frequency of a known signal;*measurement of analog modulation parameters;*phase noise measurement.

  • Handheld Audio Analyzer

    PAA3X - Phonic Corporation

    The PAA3X is a highly accurate handheld audio analyzer that gives sound engineers a rich array of sound analysis tools. The system features both 61-band and 31-band real time spectrum analysis, RT60 reverb time measurement, SPL and line meter, internal signal generator, EQ setting program, microphone calibration and speaker phase checking abilities. All functions and menus can be accessed through a central jog dial, leaving your other hand free to adjust audio settings. The large color LCD screen has an adjustable brightness to help you see in a dark or well-lit environments alike. The PAA3X also features a "screen capture" function allowing users to save images of the screen to an SD card in BMP format for later reference. The detachable precision microphone can be placed remotely via the included 5-meter extension cable, offering flexible on-site operation management. With all this plus a built-in rechargeable lithium-ion battery, the PAA3X is a must-have multifunctional tool for all serious audio engineers.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • Power Phase Converter Single phase 220VAC to 3 phase 380VAC Converter

    SDT-40KW - Zhejiang Sandi Electric Co., Ltd

    SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can?謒?apply for the three-phase electric because of space limitation.Features1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter?謒?usage, which reduced the cost of equipment investment, easy to connect wires and control.3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.9) High conversion efficiency, high instantaneous power and low load loss.10) The input voltage, output voltage, frequency and phase can be custom made.SpecificationModel SDT-40KWIsolation mode Low Frequency TransformerAC InputRated voltage (Vac) 240V single-phase 60HZVoltage range (Vac) 190-270VInput current (A) 167AAC OutputRated power (KW) 40KWRated voltage 240V ± 2%Output phases Three-phase with Neutral wires (L1, L2, L3 + N)Rated current (A) 96AOutput frequency 60Hz ±0.05 (50HZ can be set)Waveform Pure sine waveVoltage accuracy Load balancing≤1%、Unbalanced load≤5%Waveform distortion rate (THD) Linear load≤2%、Nonlinear load≤3%Dynamic Response 5%,≤50ms (load 0~100%)Power Factor (PF) 0.99Inverter Efficiency ≧85%Electrical insulation properties 2000Vac、1 MinuteProtection FunctionOverload Ability 150%、10sProtection Input under voltage, overvoltage, output over-current, short circuit, overheating etc.Display LCD+LEDMethod of working Working continuouslyCooling method Intelligent fan coolingShort-circuit protection No automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protection IP20 (indoor)Working Altitude(m) ≤3000mWorking temperature (℃) -20~+50℃Relative humidity (℃) -25~+85℃Noise (1 meter) ≤60dBReference size: (W x D x H) 750×750×1480mmReference net weight (Kg) 340Kg

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help